Speed Measurement Based on the frequency of the sensor signal. Using the principle of pulse distance, extended over a minimum period of time, programmable 5 milliseconds ... 99 seconds. Accuracy ± 0.05 % of value ± 1 in last digit. Response 1 input pulse interval + programmed minimum time + 5 milliseconds. Setpoint Alarms 2 alarms as standard both with SPDT contacts. 2 additional alarms optional with solid state electronic switch. Setpoints level individually programmable from zero speed up to any high speed. Each individually programmable in its hysteresis position and bandwidth. Alarm state individually programmable for excess, no power, starter period and input failure condition. Starter period initiated by external 24 v control signal to isolated input. Extension programmable up to 999 sec. Power handling of relay contacts 250 v, 2 amps, 100 w AC, of electronic switches 60 v, 0.1 amp DC. External overload protection required. Analog output (option) Isolated and protected against external short circuit. Current 0/4 .. 20ma with max. load of 500 ohms,
convertible to voltage 0/2 ... 10 v with max. load 10 ma. High and low end of span programmable. Resolution 12 bit (1 : 4096). Temperature drift < 0.01 % within 0 ... 40 °C (32 ... 104 °F). Long term stability < 0.25 % during 5000 hours of operation.
Signal input to sensors Isolated circuit, responding to pulse signals of any waveform, and to AC-signals. Range 0 ... 300 kHz. Response level programmable by steps. Minimum signal 50 millivolts RMS, maximum 100 volts. Impedance 100 k. Scaling factor programmable by 5 digits, to consider any relationship between signal frequency and the variable. Applicable sensors: all BRAUN sensors, or equivalent, NAMUR type sensors, tachogenerators, encoders. Sensor supply: 12 volts / max. 60 ma. Extra output 8 volts via 1 k load resistor to passive 2 leads sensor types. Input frequency divider Balances signals as from irregular profiles, if set to the repetition of the irregularity (= reduction of the sequence to one per period). Factor programmable 001... 256.
|
|
Input monitoring Short-circuit or interrupt of supply (NAMUR types also), signal lead break (requires push-pull sensor output). A detected failure sets any of the alarms to a pre-programmable state. Input signal repeating output Direct output: level 10 volts, 1 k source impedance.
Output subsequent to frequency divider: isolated opto-coupler (to max 30 volts, 10 ma). RS232 Data interface Baud rate programmable, up to 19200 Baud. Output of measurements and signals state, subsequent to request. Input for programming the parameters (equipment required see ordering information). Display 5 digits with red LED figures, 8 mm high. Indicating the variable during operation, parameters while programming.
Programming Structurized as groups for fast and easy access, manually by front keys, alternatively via RS 232. Parameters are safe-guarded against power failure, and code protected against unauthorized access. Power supply Comprehensive supply range 20 volts ...265 volts AC/DC. Power consumption approx. 7 watts. Insulation Category class 1.
Design Snap-on-track enclosure for 35 mm rail. Length 70 mm, width (including terminals) 103 mm, height 110 mm. Weight approx. 0.3 kg. Protection grade IP 20. Available in field mounting enclosure as well. Grade IP 65 / NEMA 4, with transparent cover. Suffix -G to ordering No.
Wiring 2 plug-in terminal blocks, accepting 0.2 ..2,5 mm2 cross section. RS 232 at USB Mini B front socket. Operating conditions
Ambient temperature - 20 °C ... +60 °C (-5 ... + 140 °F), Humidity max. 75 %, without dew.
Compatibility to Standards
EMI according to EN 610000-6.2, EN 610000-6-4. Safety according to EN 61010-1
|