Displays, Setpoint Alarms, Converters to analog or to data output.
Designed for permanent installation and easy programming.
-
Range from zero speed up to more than 100 kHz.
-
Precise and fast tracking response by pulse interval measurement with automatic floating period. Can be extended over a programmable minimum time for the tracking speed and averaging, as appropriate to the application.
-
Easily programmed at the unit itself, for exact adaptation to the application: number of teeth, gear ratio, decimal point in readings, span of an analog output, alarm response characteristics, starter condition.
-
Power supply by AC and DC, voltage range 18 …40 V or 85 …265 V.
-
Design option, snap-on-track enclosure (D), panel mount (C), or 19-inch rack module (E).
|
|
Choice of functional facilities:
- Analog output 20 mA/10 volts, programmable live zero, -alarms with programmable hysteresis band and position, - display by LCD or bright red LED,
- signal input with sensor monitor or with additional path for low level sensors, - adjustable input pulse divider to balance mechanical target irregularities. - Additional speed measuring channel to read ratio or difference (slip, draw, synchronism).
- Data interface output of measurements.
|

|
Basic versions
Series No.
|
design see figure |
display |
analog output |
setpoint alarms |
sensor monitor |
additional low level input |
input pulse divider |
additional measuring channel |
RS232 option |
Download
|
| 124.100 |
C, D1, E |
14mm red |
- |
- |
- |
X |
- |
X |
X |
|
| 124.112 |
C, D1, E |
14mm red |
X |
2 |
- |
X |
- |
X |
X |
|
| D421.3 |
D4 |
8mmLCD |
X |
- |
- |
X |
X |
- |
- |
|
| D421.5 |
D4 |
8mmLCD |
X |
2 |
- |
X |
X |
- |
- |
|
|
|
|
|
|
|
|
|
|
|
|
Special functions on option:
| Series No. |
Application |
design (see figure) |
analogue output |
setpoint alarms |
input to sensor series |
RS232 option |
Download
|
| 124.1S2 |
speed + direction |
C, D1, E |
X |
1+1 |
A5S3… |
X |
|
| 224.1S2 |
speed + direction + sensor failure monitor |
C, D1, E |
X |
1+1 |
A5S4… |
X |
|
| 124.1S4 |
PROFIBUS – Data Inteface |
C, D1, E |
X |
|
all |
- |
|
| 124.1S6 |
speed + acceleration |
C ,D1, E |
X |
|
all |
X |
|
| D461 |
isolating barrier to Ex-area |
D4 |
Pulse output |
A5S1… |
- |
|
|
|
|
|
|
|
|
As customized versions, we further provide such with up to 32 scaling factors (externally activated), or such with linearization function.Also such with more setpoint alarms, or with more separated analog outputs.
|
|
Speed Sensors overspeed protection
- with high degree of safety!
Ausdruck von Datenblättern bitte über die zugehörigen Downloads
|