Home Meters and Alarms for permanent Installation

Contact

Einbaugeräte | Print |

Displays, Setpoint Alarms, Converters to analog or to data output.

Designed for permanent installation and easy programming.

  • Range from zero speed up to more than 100 kHz.
  • Precise and fast tracking response by pulse interval measurement with automatic floating period.  Can be extended over a programmable minimum time for  the tracking speed and averaging, as appropriate to the application.
  • Easily  programmed at the unit itself, for exact adaptation to the application: number of teeth, gear ratio, decimal point in readings, span of an analog output, alarm response characteristics, starter condition.
  • Power supply by AC and DC, voltage range 18 …40 V  or 85 …265 V.
  • Design option, snap-on-track enclosure (D), panel mount (C), or 19-inch rack module (E).

 


Choice of functional facilities:
  • Analog output 20 mA/10 volts,   programmable live zero, -alarms with programmable hysteresis band and position, - display  by LCD or bright red LED,
    - signal input with sensor monitor or with additional path     for low level sensors,
    - adjustable input pulse divider to balance mechanical target irregularities.
    - Additional speed measuring channel to read ratio or difference (slip, draw, synchronism).
  • Data interface output of measurements.

     

 

einbaugeraete_engl2

 

 

Basic versions

 

Series No.
design
see figure
display analog
output
setpoint
alarms
sensor
monitor
additional low
level input
input pulse
divider
additional
measuring channel
RS232
option
Download
124.100 C, D1, E 14mm red - - - X - X X
pdf
124.112 C, D1, E 14mm red X 2 - X - X X
pdf
D421.3 D4 8mmLCD X - - X X - -
pdf
D421.5 D4 8mmLCD X 2 - X X - -
pdf

 

 

Special functions on option:

 

Series No. Application design
(see figure)
analogue
output
setpoint
alarms
input to
sensor series
RS232
option
Download
124.1S2 speed + direction C, D1, E X 1+1 A5S3… X
pdf
224.1S2 speed + direction + sensor failure monitor C, D1, E X 1+1 A5S4… X
pdf
124.1S4 PROFIBUS – Data Inteface C, D1, E X all -
pdf
124.1S6 speed + acceleration C ,D1, E X all X
pdf
D461 isolating barrier to Ex-area D4 Pulse output A5S1… -
pdf

 

As customized versions, we further provide such with up to 32 scaling factors (externally activated), or such with linearization function.Also such with more setpoint alarms, or with more separated analog outputs.

 



 

Speed Sensors overspeed protection

- with high degree of safety!

 

 

Ausdruck von Datenblättern bitte über die zugehörigen Downloads