Application Characteristics
-
For all applications where the sense of motion is a critical factor: feeding pumps, the turn gear of a turbine, the automatic testing equipment for electric hand tools, for instance.
Direction Signal The unit not only converts the immediate electronic direction signal from the sensor to an isolated relay SPDT signal. For this assignment, it offers a programmable selection of definitions:
-
Motion controlled delay of the reverse signal:
The reverse condition will not be released until a (programmable) number of pulses in reverse direction has occurred, within a (programmable) period of time. Thus, a slight reverse motion or oscillation at the machine stop will not result in an unwanted reverse signal. It will not be released, before the machines resumes a certain reverse speed. The "forward" signal however will appear without delay after one pulse in forward sense.
-
Attachment to zero speed:
Per program, the direction signal may alternatively be tied to a zero speed status, which is detected at a designated level (see speed measurement). The thus enforced signal can be programmed to be forward or reverse.
-
Double pole contact signal:
The second relay output of the unit, normally assigned to a setpoint controlled speed alarm, may be joined to the direction section per program. A double poled relay signal thus is achieved, useful for instance, to reverse the analog speed signal provided.
Direction signal output: With standard (default) programming, one relay signals the direction by its SPDT contact, following one of the above criteria. Per program, the relay position at no power can be assigned to forward or reverse motion. If required, the second relay output of the unit, normally assigned to a programmable speed alarm, may be joined to the direction section per program. Thereby, a twin circuits SPDT signal is achieved, useful for instance, to reverse the analog speed signal provided.
Power handling facility of each SPDT contact:
max 250 v/2 amp AC resp. 100 watts DC. External overload protection required.
Compatibility to Standards
EMI according to EN 610000-6.2, EN 610000..-6.4,
Safety according to EN 61010-1
|
|
Speed Measurement This section utilizes the pulse train, as additionally provided by the A5S30 ..33 sensors. It uses the advantageous measuring principle, distinguished by quartz controlled pulse distance evaluation, automatically extended over a programmable minimum period of time. The ideal combination of fast response and averaging of measurements, as appropriate to the application. By the 5-digits scaling facility, any required reading can be established. Measuring accuracy ± 0.01 % ± 1 in last significant digit. Minimum time extension for every measuring period programmable 30 millisec up to 10 seconds. The programmable low end of the speed range determines the aforementioned zero speed criterion selectable for the direction signal. Speed Setpoint Alarm Output with SPDT relay contact. Response characteristics individually programmable: setpoint, hysteresis bandwidth and location, condition at no power and during starter period. Response delay approx. 5 millisec + measuring period. Power handling max 250 v/2 amp AC resp. 100 watts DC, overload protection required. Display 5 digit, with bright red figures. Versions C and D have 14 mm height, version E uses 8 mm. Decimals and blank zeroes can be programmed. The display update sequence may be increased beyond the minimum period. During the programming phase, the display reads the step number and its corresponding parameter. Direction indicated by a red LED on/off. Sensor Input Compatible with any sensor of series A5S30....A5S33, including its supply. Likewise, the unit can operate with corresponding signals from a sensor of series A5S14... A5S17 installed in a hazardous Ex-area, if transmitted via an Isolating Barrier D461.21. Other sources, if used, must provide the same signals: a pulse train signal with its frequency representing the speed and a binary signal indicating forward/reverse, both with hi/lo level >+7/<+4 v, into an input impedance of 100 kohms. Frequency range 0 - 100 kHz.
Power Supply Options
18...40 volts AC/DC (suffix U1 to model No) 85..265 volts AC/DC (suffix U2 to model No)
Power consumption approx 5 VA.
Operating Conditions
Ambient temperature 0°C ... +50 °C (30 ...95 °F).
Optionally, the snap-on-track version (D) is available with extended temperature range -25 ... + 65 °C (suffix M to model No).
Humidity max 70%, without condensation.
Insulation Category I
|